Model: ASR-9010-AC Cisco ASR 9010 Series Chassis
Detail: Cisco ASR 9010 Chassis ASR-9010-AC ASR-9010 AC Chassis
was $12,100.00 Special Price $6,655.00
Availability: In stock
SKU
asr-9010-ac

ASR-9010-AC specifications

Description Cisco ASR 9010 Chassis, ASR-9010-AC, ASR-9010 AC Chassis

Cisco ASR 9010 Specs

Physical specifications Height: 36.75 in. (933.45 mm) (21 RU) Width: 17.38 in. (441.45 mm) Depth: ●  With doors: 29.03 in. (737.4 mm) ●  Without doors: 28.24 in. (717.3 mm) Weight: ●  155.6 lb (70.73 kg) (chassis with PEM) 231.6 lb (105.27 kg) (fully loaded, excluding linecards and power modules) – RSP, two v2 fan trays, PEMs
Slot orientation Vertical
Cisco ASR 9000 Series RSP Dual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards 8 line-card slots
“Commons” components 2 RSPs 2 fan trays 2 PEMs (either DC or AC) 1 fan filter
Reliability and availability Fabric redundancy Fan redundancy Feed redundancy Power-supply redundancy RSP redundancy Software redundancy
Rack mounting 19-in. default 21- and 23-in. adapters available Note: Minimum 17.75-in. opening between posts is needed for proper operation
Cabinet mounting Yes Note: Doors not recommended in enclosed cabinets
Wall mounting No
Airflow Front-to-back

Performance

Fabric One per RSP: ●  Active/active nonblocking operation mode in dual-RSP redundant configuration ●  Fully redundant in dual-RSP redundant configuration ●  Built-in service-intelligence and traffic-prioritization capability
Thermal Two fan trays: ●  12 high-efficiency fans per tray ●  Variable-speed fans for optimal thermal performance ●  No single point of failure
Modularity Pay-as-you-grow power for future scalability, available in AC and DC. Multiple power module types: ●  6 kW and 3 kW AC power modules ●  4.4 kW and 2.1 kW DC power modules Note: Mixing of AC and DC modules is not supported
Redundancy ●  AC: N+N redundancy ●  DC: N+1 redundancy ●  Power module redundancy ●  A/B Feed redundancy ●  PEM redundancy
Power zones No power zone restrictions Fully load-sharing power infrastructure
Power input Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum) Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
Power-module airflow Front-to-back

Environmental Specifications

Operating temperature (nominal) 41 to 104ºF (5 to 40ºC)
Operating temperature (short-term) ASR 9006: 23 to 131ºF (-5 to 55ºC) ASR 9010: 23 to 122ºF (-5 to 50ºC)
Operating humidity (nominal) (relative humidity) 5 to 90%
Storage temperature -40 to 158ºF (-40 to 70ºC)
Storage (relative humidity) 5 to 93%
Operating altitude -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)

Regulatory Compliance

Network Equipment Building Standards (NEBS) Cisco ASR 9010 Routers are designed to meet: ●  SR-3580: NEBS Criteria Levels (Level 3) ●  GR-1089-CORE: NEBS EMC and Safety ●  GR-63-CORE: NEBS Physical Protection ●  VZ.TPR.9205: Verizon TEEER
ETSI standards Cisco ASR 9010 Routers are designed to meet: ●  EN300 386: Telecommunications Network Equipment (EMC) ●  ETSI 300 019 Storage Class 1.1 ●  ETSI 300 019 Transportation Class 2.3 ●  ETSI 300 019 Stationary Use Class 3.1
EMC standards emission Cisco ASR 9010 Routers are designed to meet: ●  FCC Class 47CFR15 A ●  ICES 003 Class A ●  AS/NZS CISRP22 Class A ●  CISPR 22 (EN55022) Class A ●  VCCI Class A ●  BSMI Class A ●  IEC/EN 61000-3-12: Power Line Harmonics ●  IEC/EN 61000-3-11: Voltage Fluctuations and Flicker ●  EN55022: Information Technology Equipment (Emissions) ●  EN 50121-4: Railway EMC
EMC standards immunity Cisco ASR 9010 Routers are designed to meet: ●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) ●  IEC/EN-61000-4-3: Radiated Immunity (10V/m) ●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) ●  IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) ●  IEC/EN-61000-4-5: Signal Surge Ports (1kV) ●  IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM) ●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) ●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) ●  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations ●  EN55024: Information Technology Equipment (Immunity) ●  EN50082-1/EN-61000-6-1: Generic Immunity Standard ●  EN 50121-4: Railway EMC
Safety Cisco ASR 9010 Routers are designed to meet: ●  UL/CSA/IEC/EN 60950-1 ●  IEC/EN 60825 Laser Safety ●  ACA TS001 ●  AS/NZS 60950 ●  FDA Code of Federal Regulations Laser Safety