cisco-ie-2000u-8tc-g.jpg

IE-2000U-8TC-G

cisco-ie-2000u-4t-g.jpg

IE-2000U-4T-G

cisco-ie-2000u-16tc-g-x.jpg

IE-2000U-16TC-G-X

IE-2000U-8TC-G

Model: IE-2000U-8TC-G - Industrial Ethernet 2000 Series
Detail: IE 2000U 8 x 10/100,2 T/SFP GE ports with 1588
was $2,482.00 Special Price $1,227.00
Availability: In stock
SKU
ie-2000u-8tc-g

IE-2000U-8TC-G Specification

Total Ports

10

RJ45 Ports

8 FE

Combo Ports

2 GE

IEEE 1588

Yes

PRP

Yes

Software

LAN Base

Dimensions (H x W x D), Including DIN Rail

5.1 x 3.6 x 5.26 in (130 x 91.4 x 134 mm)

Weight

3.45 lbs (1.56 kg)

Hardware

●  256 MB DRAM with ECC memory

●  1 GB removable SD flash memory card (CG swap drive) – (128MB space available)

●  Mini-USB connector

Alarm

●  Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max

Power Supply

●  Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum

●  Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC

Power Consumption

10-port models: 11-16 W

Substation Compliance

●  IEC 61850-3

●  IEEE1613

Hazardous Location

●  ANSI/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure)

●  UL/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure)

●  EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure)

●  IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure)

●  CSA 213

Industrial Control Safety

●  UL508

●  CSA C22.2 No. 142

EMC Interface Immunity

●  EN 55024 (CISPR 24)

●  AS/NZS CISPR 24

●  KN 24

●  IEC61000-4-2 (Criteria A - Class 2)

●  IEC61000-4-3/ENV50204 (Criteria A)

●  IEC61000-4-4 (Criteria A/Criteria B)

●  IEC61000-4-5 (Criteria B)

●  IEC61000-4-6 (Criteria A)

Standard Electromagnetic Emissions Certifications

●  FCC Part 15 Class A

●  EN 55022 Class A (CISPR22 Class A)

●  ICES-003 Class A

●  EN 300 386

●  VCCI Class A

●  AS/NZS CISPR22 Class A

●  CNS 13438 Class A

●  KN 22 Class A CE Marking

Standard Safety Certifications

●  UL 60950-1

●  CSA 60950-1

●  EN 60950-1

●  IEC 60950-1, CB report and certificate with all national differences

Operating Environment

●  Operating Temperature: -40C to +75C

●  -40C to +70C (Vented Enclosure – 40 LFM Air Flow)

●  -40C to +60C (Sealed Enclosure – 0 LFM Air Flow)

●  -34C to +75C (Fan or Blower equipped Enclosure – 200 LFM Air Flow)

●  -40 to +85C (IEC 60068-2-2 Environmental Type testing - 100 hours)

●  Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009:

●  Relative humidity: 5% to 95% non-condensing

Storage Environment

●  Temperature: -50º C to +85º C

●  Altitude: 15,100 ft (4600 m)

Warranty

●  Five-year limited warranty on all IE-2000U HW PIDs

Mean Time Between Failure (MTBF)

●  700,760 Hours

Protection Class Code

●  IP30 per EN60529