N3K-C3064PQ-10GX
Model: | N3K-C3064PQ-10GX - Cisco Nexus 3000 Series |
Detail: | Nexus 3064-X, 48 SFP+ and 4 QSFP+ ports, with enhanced scale, low latency |
N3K-C3064PQ-10GX Specification |
||
Physical |
● 1RU fixed form factor ● Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+) ◦ 48 SFP ports support 1 and 10 Gigabit Ethernet ◦ 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each ● 2 redundant power supplies ● 1fan tray with redundant fans ● 1 I/O module with management, console, and USB flash memory ports |
|
Performance |
● 1.28-Tbps switching capacity ● Forwarding rate of 950 mpps ● Line-rate traffic throughput (both Layer 2 and 3) on all ports ● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
|
Hardware tables and scalability |
MAC addresses |
128,000 |
Number of VLANS |
4096 |
|
Spanning-tree instances |
● Rapid Spanning Tree Protocol (RSTP): 512 ● Multiple Spanning Tree (MST) Protocol: 64 |
|
ACL entries |
● 2000 ingress ● 1000 egress |
|
Routing table |
● 16,000 prefixes and 16,000 host entries ● 8000 multicast routes |
|
Number of EtherChannels |
64 (with vPC) |
|
Number of ports per EtherChannel |
32 |
|
Buffers |
9 MB shared |
|
Boot flash memory |
2 GB |
|
Power |
Number of power supplies |
2 ● Cisco Nexus 3064-X: Redundant for AC and DC power |
Power supply types |
● AC (forward and reversed airflow) ● DC (forward and reversed airflow) |
|
Typical operating power |
● Cisco Nexus 3064-X ◦ 143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs]) ◦ 177W (64p with SR optics at 100% load; 2 PSUs) |
|
Maximum power |
● Cisco Nexus 3064-X: 199W |
|
AC PSUs ● Input voltage ● Frequency ● Efficiency |
● 100 to 240 VAC ● 50 to 60 Hz ● 89 to 91% at 220V |
|
DC PSUs ● Input voltage ● Maximum current ● Efficiency |
● -40 to -72 VDC ● 33A ● 85 to 88% |
|
Typical heat dissipation |
● Cisco Nexus 3064-X ◦ 488 BTU/hr (64p with Twinax at 100% load; 2 PSUs) ◦ 605 BTU/hr (64p with SR optics at 100% load; 2 PSUs) |
|
Maximum heat dissipation |
● Cisco Nexus 3064-X: 683 BTU/hr |
|
Cooling |
Forward and reversed airflow schemes: ● Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports) ● Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies) Single fan tray with redundant fans Hot swappable (must swap within 1 min) |
|
Sound |
Measured sound power (maximum) ● Fan speed: 40% duty cycle ● Fan speed: 60% duty cycle ● Fan speed: 100% duty cycle |
● 59.7 dBA ● 66.4 dBA ● 71.0 dBA |
Environment |
Dimensions (height x width x depth) |
● Cisco Nexus 3064-X: 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
Weight |
● Cisco Nexus 3064-X: 20.5 lb (9.3 kg) |
|
Operating temperature |
32 to 104°F (0 to 40°C) |
|
Storage temperature |
-40 to 158°F (-40 to 70°C) |
|
Operating relative humidity |
● 10 to 85% noncondensing ● Up to 5 days at maximum (85%) humidity ● Recommend ASHRAE data center environment |
|
Storage relative humidity |
5 to 95% noncondensing |
|
Altitude |
0 to 10,000 ft (0 to 3000m) |