N3K-C3524P-10G
Model: | Cisco N3K-C3524P-10G Nexus 3500 Series Switch |
Detail: | Cisco Nexus N3K-C3524P-10G Switch Layer 2 and layer 3 - 24 x 10G SFP+ active Ethernet ports - Ultra-Low latency - Managed |
N3K-C3524P-10G Specification |
||
Product Number |
N3K-C3524P-10G |
|
Product Description |
Cisco Nexus N3K-C3524P-10G Switch Layer 2 and layer 3 - 24 x 10G SFP+ active Ethernet ports - Ultra-Low latency - Managed |
|
Physical |
● 24 fixed SFP+ ports (1 or 10 Gbps); expandable to 48 ports ● Dual redundant hot-swappable power supplies ● Four individual redundant hot-swappable fans ● One 1-PPS timing port, with the RF1.0/2.3 QuickConnect connector type* ● Two 10/100/1000-Mbps management ports ● One RS-232 serial console port ● One USB port ● Locator LED ● Locator LED button |
|
Performance |
● 480-Gbps switching capacity ● Forwarding rate of 360 mpps ● Line-rate traffic throughput (both Layer 2 and 3) on all ports ● Configurable MTUs of up to 9216 bytes (jumbo frames) |
|
Typical operating power |
● 142W |
|
Maximum power |
● 245W |
|
Typical heat dissipation |
● 484 BTUs per hr |
|
Maximum heat dissipation |
● 835 BTUs per hr |
|
Mode |
Normal Mode |
Warp Mode |
Number of MAC addresses |
64,000 |
8000 |
Number of IPv4 unicast routes |
24,000 |
4,000 |
Number of IPv4 hosts |
64,000 |
8000 |
Number of IPv4 multicast routes |
8000 |
8000 |
Number of VLANS |
4096 |
|
Number of ACL entries |
4096 |
|
Number of spanning-tree instances |
Rapid Spanning Tree Protocol (RSTP): 512 Multiple Spanning Tree (MST) Protocol: 64 |
|
Number of EtherChannels |
24 |
|
Number of ports per EtherChannel |
24 |
|
Buffer size |
6 MB shared among 16 ports; 18 MB total |
|
Boot flash memory |
2 GB (3524P and 3548P models) 4 GB (3524X and 3548X models) |
|
Power |
||
Number of power supplies |
2 (redundant) |
|
Power supply types |
● AC (forward and reversed airflow) ● DC (forward and reversed airflow) |
|
Input voltage |
100 to 240 VAC |
|
Frequency |
50 to 60 Hz |
|
Power supply efficiency |
89 to 91% at 220V |
|
Cooling |
Forward and reversed airflow schemes ● Forward airflow:Port-side exhaust (air enters through fan tray and power supplies and exits through ports) ● Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies) Four individual, hot-swappable fans (3+1 redundant) |
|
Environment |
||
Dimensions (height x width x depth) |
1.72 x 17.3 x 18.38 in. (4.36 x 43.9 x 46.7 cm) |
|
Weight |
17.4 lb (7.9 kg) |
|
Operating temperature |
32 to 104° F (0 to 40°C) |
|
Storage temperature |
-40 to 158° F (-40 to 70°C) |
|
Relative humidity (operating) |
● 10 to 85% noncondensing ● Up to 5 days at maximum (85%) humidity ● Recommend ASHRAE data center environment |
|
Relative humidity (nonoperating) |
5 to 95% noncondensing |
|
Altitude |
0 to 10,000 ft (0 to 3000m) |